<ErrorNumber>17696</ErrorNumber>
<ErrorFamily>Exposure Head</ErrorFamily>
<ErrorMessage>
HEAD: Stroke Clock or Imaging signal fault, check LC-BP cable (OR)
Stroke Clock fault (bipolar)
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Thermal</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
In order to image properly, the head requires the SCLK and IMAGING signals from
the MPE. These signals are in the DB9 connector (LC-BP cable) between the MPE
backplane and the head. If these signals are not detected during a plot, this
error will be generated.
</text></DescriptionText>
<DescriptionText><text>
A hotlink fault can also cause this problem.  If replacing the LC-BP cable doesn't
clear the fault, then there may be a faulty hotlink connection.
</text></DescriptionText>
<DescriptionText><text>
If replacing the cables doesn't solve the problem, then there is most likely a
connection fault with the cabling inside the top cover of the head.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Replace the LC-BP cable, and if that doesn't work, replace the hotlink cable.
</text></DescriptionText>
</OperatorAction>
<Cause>
SCLK or IMAGING signal not received by the head.
</Cause>
<Cause>
Hotlink fault.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:42 2008 PST
</Updated>
<Links>
</Links>
</Error>